How To Repair The Notch On Vertical Blinds
How to Supplant Bali and Graber Vertical Blind Stems and Gears in G98 Headrails
Introduction
This guide demonstrates how to replace the stem and gear on Bali Magnum and Graber G-98 Ultra-Vue vertical bullheaded headrails. First, we'll walk through replacing the stem and gear on a standard carrier. You can practise these repairs with the blind hanging. Then, we'll tackle the more complicated stem and gear replacement on the master carrier. For repairs to the chief carrier, the blind will need to come out of the window.
Tools Needed
Tools Needed if Working on the Master Carrier
Needle-Nose Pliers
Regular (Sideslip Joint) Pliers
Phillips Screwdriver
Work Gloves
Parts Needed
Parts Needed if Working on the Principal Carrier
Step 1– Showtime, let's expect at how the stalk and gear fit together. There are two small-scale tabs on the end of the clip that have to be compressed to separate it from the gear. Special pliers must be used.
Stride ii - Now, we'll replace a stem on a standard carrier. Make sure that the stems are perpendicular to the headrail so that y'all tin can admission the tabs on the stem. Use the pliers to firmly squeeze the tabs on the stop of the stem. Set the pliers down and pull the stalk free from the carrier. This repair can be washed with the blind hanging in the window if you lot prefer.
Step iii - To remove the gear, just push button it out of the side of the carrier. If the blinds are hanging up, be sure that the minor gear doesn't fall down in the heat register.
Step iv - Slide a new gear into the carrier. There are two different sides to the gear. The flat side goes toward the flooring when the blinds are hanging.
Step five - Insert a new clip into the gear and carrier. The nub needs to confront the same direction as the others. The small notch needs to fit into the gear properly.
Step 6 - If the new stem isn't lined upwards perfectly with the others, that's OK. These blinds are cocky-aligning and can correct themselves. To get the blinds to self-align, twist the wand all of the way in ane direction and then all the style to the other direction. This will align the stems.
Step seven - To replace the stem or gear on the master carrier, the whole tilt control must be replaced. We recommend removing the blind from the window for this repair. To begin, remove the wand from the tilt control, and set up it bated to reuse. Utilise needle-nose pliers to separate the metallic band the wand is attached with.
Footstep viii - Remove the small screws from both ends of the headrail.
Stride ix - Remove the end caps from both ends of the headrail. The headrails can be abrupt and nosotros recommend wearing work gloves to protect your hands from cuts.
Pace 10 - Push all of the carriers down toward the end with the wand command until the railroad train starts to come out of the headrail. Now, use needle-nose pliers to remove the push button nut retainer from the terminate of the tilt rod on the side past the tilt command machinery. Remove the plastic idle stop slice.
Pace eleven - To remove the tilt control, shrink the small metal notch that is sticking up. Now, the tilt control will slide off of the tilt rod.
Step 12 - Put the new tilt control associates onto the tilt rod. Be sure to line up the notch in the tilt command with the notch on the tilt rod.
Step thirteen - Insert the metal spacer strip into the slot on the tilt control. Utilize the needle-nose pliers to rebend the tab.
Footstep xiv - Put the idle end dorsum on with the 5-shape facing the top of the blinds.
Step 15 - Put a new push nut rod retainer onto the tilt rod. Make note of where the one-time i was and put the new one in the same position. Use needle-nose pliers to work the new button nut into position if you don't have a nut driver tool.
Step 16 - Slide all of the carriers and tilt control back into the headrail. Exist careful that the spacer straps don't become caught.
Step 17 - Slide the idle end back to the end of the headrail, and reattach both of the cease caps. Remember to utilize a glove to protect your manus from the potentially sharp edges of the headrail.
Footstep 18 - Reattach the wand. Put the metallic ring through the eyelet on the tilt mechanism. Hold the ring with pliers and insert the wand on information technology. Squeeze the ring closed with the pliers.
Pace 19 - Allow's go the new stem to confront the same direction every bit all of the others. To get the blinds to self-align, twist the wand all of the mode in one management and so all the style to the other direction. This volition align the stems. Then, slide the carriers beyond the headrail with the wand to make sure everything is operating properly.
Footstep 20 - Reinstall the screws into each end cap of the headrail.